
- #AVIGILON CONTROL CENTER CLIENT TIMEOUT SERIAL#
- #AVIGILON CONTROL CENTER CLIENT TIMEOUT DRIVER#
- #AVIGILON CONTROL CENTER CLIENT TIMEOUT PASSWORD#
Telegram I/O Server: camera images and generic image files can now be sent via Telegram messages.Tecnoalarm I/O Server: added data point "log0".added support for Strato Pi CAN and Strato Pi CM Duo.
#AVIGILON CONTROL CENTER CLIENT TIMEOUT PASSWORD#
new password = command overrides the password configuration parameter. new user = command overrides the user configuration parameter. new connection = close command: closes the SSH connection. Sets the command execution timeout in seconds defaults to 30 Using it doesn't decrease the number of available I/O servers player state is now restored after a track is played via ".play = " or via public announcement. added support for SONOS firmware version 9. Protege I/O Server: new I/O Server for the ICT ProtegeGX security panel. Philips Hue I/O Server: added support for Hue White devices. Paradox I/O Server: new "log0" data point. NetworX I/O Server: added possibility to specify zone names. MyHome I/O Server: added support for HMAC authentication (for MyHome Server 1 and other recent OpenWebNet gateways). MQTTBROKER and MQTTCLIENT I/O Servers: new I/O servers add support for the MQTT protocol, client and broker. MPOWER I/O Server: new I/O Server for the Ubiquity mFi mPower controllable power outlets. high-availability: when "shutdown when inactive" is true and the HSYCO Server is inactive, all Modbus calls are affectively blocked, and return null. #AVIGILON CONTROL CENTER CLIENT TIMEOUT SERIAL#
When the Modbus TCP gateway option is enabled, setting tcpmodbuseventunitid to a Unit Id value (0 to 255) will redirect all TCP requests to that Unit Id to the ModbusEvent() callback instead of the Modbus RTU serial bus
MasterBus I/O Server: new I/O Server for Mastervolt's MasterBus. LoRaWAN I/O Server: new I/O Server for LoRaWAN Network and Application servers implementation. IONO PI Max I/O Server: new I/O Server for Sfera Labs Iono Pi Max. added support for local Iono Pi direct access. #AVIGILON CONTROL CENTER CLIENT TIMEOUT DRIVER#
added support for iono pi driver v1.3.0 and "wiegandbits" option."minvariation" option now also applies to polling mode.IFTTT I/O Server: new I/O Server for the IFTTT service.KSENIA I/O Server: new I/O Server for the KSENIA lares security panels.
added "initreadinterval" I/O Server option.
KILSEN I/O Server: new I/O Server for the KILSEN fire alarm panels. added ".json" and ".pre.json" datapoints. added support for "middle" luminance level. ELMO I/O Server: added support for Pregio, Vidomo (Villeggio series), Proxima and Titania panels. default number of lights, dimmers, automation is 0 (zero). new HTTP API: data points can now be set and read remotely with the /x/httpcall HTTP API. DUELUX I/O Server: new I/O Server for the Duemmegi DUELUX DLCP DALI-2 system controller. high availability support for redundant DFH installations.
support of position information and commands for DFTP, DFTP/I.support of DF8RIT configuration with temperature input address enabled and temperature control disabled.support of DF4RI/DF4RIR virtual outputs.
Dea Xensity I/O Server: new I/O Server for the Dea Xensity indoor shock detectors. support of MODDALI firmware version 6.x. AVIGILON I/O Server: new I/O Server for the Avigilon Control Center 7. verbose log output of XML content posted to server and return data. Aritech Comfort CSx75 I/O Server: added possibility to specify zone names.